Activator II V VII X

Description General information Package
insert
Remarks
Diamed Diaplastin E Reagent: Liquid

Reagent source: Rabbit brain combined with Calcium/Thromboplastin

ISI: In the range of 1.1

Interferences: High sensitivity to Factor II, V, VII, X

Helena Bioscience Thromboplastin

Reagent: Lyophilized

Reagent Source: Rabbit brain tissue

ISI: Between 2.0 and 2.5

I.L. HemosIL PT-Fibrinogen I.L. HemosIL PT- Fibrinogen

Reagent: Lyophilized

Reagent source: Rabbit-brain

ISI: Range approximately 2.0

Interferences: Insensitive up to 1 U/ml of Heparin

I.L. HemosIL PT-Fibrinogen – HS Plus I.L. HemosIL PT-Fibrinogen – HS Plus

Reagent: Lyophilized

Reagent source: Rabbit-brain

ISI: Range approximately 1.2

Interferences: Insensitive up to 0.5 U/ml of Heparin, extrinsic factor sensitive

I.L. HemosIL Recombiplastin 2G I.L. HemosIL Recombiplastin 2G

Reagent: Liquid

Reagent source: Recombinant human tissue factor

ISI: Range approximately 1.00 on ACL systems

Interferences:  Insensitive up to 1.0 U/ml of Heparin, extrinsic factor sensitive.

MediRox Owren’s PT

Reagent: Lyophilized

Reagent source: Based on bovine plasma

Nycomed Thrombotest

Reagent: Lyophilized

Reagent source: Bovine brain thromboplastin and adsorbed bovine plasma

ISI: 1.0

Interferences: Sensitive to the depression of factors II, VII and X as well as to the presence of PIVKA factors

Nycomed Nycotest

Reagent: Lyophilized

Reagent source: Rabbit brain thromboplastin and adsorbed bovine plasma

ISI: 1.0

Interferences: Sensitive to the depression of factors II, VII and X. Insensitive to heparin in therapeutic doses

Pacific Hemostasis Thromboplastin-DS

Reagent source: Rabbit brain thromboplastin

ISI: Target ISI value of 1.0 to 1.3

Siemens Actin FS Interferences: Sensitive for the detection of factor deficiences of the intrinsic system, Moderate sensitive to lupus anticoagulans and high sensitive to heparin
Siemens Innovin

Reagent source: Purified recombinant human tissue factor combined with synthetic phospholipids

Interferences: High sensitive to extrinsic factor deficiences and oral anti-coagulant, insensitive to therapeutic levels of heparin

Siemens Pathromtin SL Interferences: High sensitive to lupus anticoagulans, factor deficiences and heparin
Siemens Thromboplastin C Plus Reagent source: Dried rabbit brain thromboplastin
Siemens Thromborel S

Reagent source: Human placental tissue factor

Interferences: High sensitive to factor II, V, VII and X

Stago Neoplastin CI

Reagent: Lyophilized

Reagent source: Thromboplastin prepared from fresh rabbit cerebral tissues

Interferences: The reagent exhibits a low turbidity and does not sediment, insensitive to heparin

Stago Neoplastin CI Plus

Reagent: Lyophilized

Reagent source: Thromboplastin prepared from fresh rabbit cerebral tissues

Interferences: The reagent exhibits a low turbidity and does not sediment, insensitive to heparin

Stago STA Neoplastin CI

Reagent: Lyophilized

Reagent source: Thromboplastin prepared from fresh rabbit cerebral tissues

Interferences: Insensitive to heparin

Stago STA Neoplastin CI Plus

Reagent: Lyophilized

Reagent source: Thromboplastin prepared from fresh rabbit cerebral tissues

Interferences: Insensitive to heparin

Stago STA Neoplastin R

Reagent: Lyophilized

Reagent source: Thromboplastin (human recombinant tissue factor and phospholipids)

Tcoag TriniCLOT PT Excel Reagent source: Tissue thromboplastin reagent (rabbit brain)
Tcoag TriniCLOT PT Excel S Reagent source: Tissue thromboplastin reagent (rabbit brain)
Tcoag TriniCLOT PT HTF Reagent source: Tissue thromboplastin reagent derived from cultured human cells
Technoclone Technoplastin HIS Technoclone Technoplastin HIS  

Reagent: Lyophilized

Reagent source: Rabbit brain tissue

ISI: About 1.2

Interferences: Sensitive to decreased factors II, V, VII and fibrinogen level, insensitive to Heparin