Diamed Diaplastin E | Reagent: Liquid
Reagent source: Rabbit brain combined with Calcium/Thromboplastin ISI: In the range of 1.1 Interferences: High sensitivity to Factor II, V, VII, X |
||
Helena Bioscience Thromboplastin |
Reagent: Lyophilized Reagent Source: Rabbit brain tissue ISI: Between 2.0 and 2.5 |
||
I.L. HemosIL PT-Fibrinogen | I.L. HemosIL PT- Fibrinogen | ![]() |
Reagent: Lyophilized Reagent source: Rabbit-brain ISI: Range approximately 2.0 Interferences: Insensitive up to 1 U/ml of Heparin |
I.L. HemosIL PT-Fibrinogen – HS Plus | I.L. HemosIL PT-Fibrinogen – HS Plus | ![]() |
Reagent: Lyophilized Reagent source: Rabbit-brain ISI: Range approximately 1.2 Interferences: Insensitive up to 0.5 U/ml of Heparin, extrinsic factor sensitive |
I.L. HemosIL Recombiplastin 2G | I.L. HemosIL Recombiplastin 2G | ![]() |
Reagent: Liquid Reagent source: Recombinant human tissue factor ISI: Range approximately 1.00 on ACL systems Interferences: Insensitive up to 1.0 U/ml of Heparin, extrinsic factor sensitive. |
MediRox Owren’s PT |
Reagent: Lyophilized Reagent source: Based on bovine plasma |
||
Nycomed Thrombotest |
Reagent: Lyophilized Reagent source: Bovine brain thromboplastin and adsorbed bovine plasma ISI: 1.0 Interferences: Sensitive to the depression of factors II, VII and X as well as to the presence of PIVKA factors |
||
Nycomed Nycotest |
Reagent: Lyophilized Reagent source: Rabbit brain thromboplastin and adsorbed bovine plasma ISI: 1.0 Interferences: Sensitive to the depression of factors II, VII and X. Insensitive to heparin in therapeutic doses |
||
Pacific Hemostasis Thromboplastin-DS |
Reagent source: Rabbit brain thromboplastin ISI: Target ISI value of 1.0 to 1.3 |
||
Siemens Healthineers Actin FS | Interferences: Sensitive for the detection of factor deficiences of the intrinsic system, Moderate sensitive to lupus anticoagulans and high sensitive to heparin | ||
Siemens Healthineers Innovin |
Reagent source: Purified recombinant human tissue factor combined with synthetic phospholipids Interferences: High sensitive to extrinsic factor deficiences and oral anti-coagulant, insensitive to therapeutic levels of heparin |
||
Siemens Healthineers Pathromtin SL | Interferences: High sensitive to lupus anticoagulans, factor deficiences and heparin | ||
Siemens Healthineers Thromboplastin C Plus | Reagent source: Dried rabbit brain thromboplastin | ||
Siemens Healthineers Thromborel S |
Reagent source: Human placental tissue factor Interferences: High sensitive to factor II, V, VII and X |
||
Stago Neoplastin CI |
Reagent: Lyophilized Reagent source: Thromboplastin prepared from fresh rabbit cerebral tissues Interferences: The reagent exhibits a low turbidity and does not sediment, insensitive to heparin |
||
Stago Neoplastin CI Plus |
Reagent: Lyophilized Reagent source: Thromboplastin prepared from fresh rabbit cerebral tissues Interferences: The reagent exhibits a low turbidity and does not sediment, insensitive to heparin |
||
Stago STA Neoplastin CI |
Reagent: Lyophilized Reagent source: Thromboplastin prepared from fresh rabbit cerebral tissues Interferences: Insensitive to heparin |
||
Stago STA Neoplastin CI Plus |
Reagent: Lyophilized Reagent source: Thromboplastin prepared from fresh rabbit cerebral tissues Interferences: Insensitive to heparin |
||
Stago STA Neoplastin R |
Reagent: Lyophilized Reagent source: Thromboplastin (human recombinant tissue factor and phospholipids) |
||
Tcoag TriniCLOT PT Excel | Reagent source: Tissue thromboplastin reagent (rabbit brain) | ||
Tcoag TriniCLOT PT Excel S | Reagent source: Tissue thromboplastin reagent (rabbit brain) | ||
Tcoag TriniCLOT PT HTF | Reagent source: Tissue thromboplastin reagent derived from cultured human cells | ||
Technoclone Technoplastin HIS | Technoclone Technoplastin HIS | ![]() |
Reagent: Lyophilized Reagent source: Rabbit brain tissue ISI: About 1.2 Interferences: Sensitive to decreased factors II, V, VII and fibrinogen level, insensitive to Heparin |